The following is an introduction to 1-2 Coax Cable, I hope to help you better understand 1-2 Coax Cable. Welcome new and old customers to continue to cooperate with us to create a better future together!
project |
material |
diameter(mm) |
1.inner conductor |
silver plated copper wire |
7X0.102 |
2.insulator |
Polyperfluoroethylene propylene(FEP) |
0.88 |
3.outer conductor |
silver plated copper wire braid |
Nom.1.10 |
4.jacket |
Polyperfluoroethylene propylene(FEP) |
1.37 |
capacitance(pF/m) |
96 |
impedance(ohm) |
50 |
Transmission rate(%) |
70 |
working frequency(GHz) |
6.0 |
Maximum working voltage(Vrms) |
1000 |
range of working temperature(℃) |
-55~+200 |
Minimum bending radius(mm) |
4 |
ROHS environmental |
meets |
frequency(GHz) |
attenuation(dB/m) |
1.0 |
1.6 |
2.0 |
2.3 |
3.0 |
2.9 |
4.0 |
3.4 |
5.0 |
4.0 |
6.0 |
4.3 |
project |
material |
diameter(mm) |
1.inner conductor |
silver plated copper wire |
7X0.08 |
2.insulator |
Polyperfluoroethylene propylene(FEP) |
0.68 |
3.outer conductor |
Double layer tinned copper wire braid |
Nom.1.10 |
4.jacket |
Polyperfluoroethylene propylene(FEP) |
1.32 |
capacitance(pF/m) |
95.6 |
impedance(ohm) |
50 |
Transmission rate(%) |
70 |
working frequency(GHz) |
6.0 |
Maximum working voltage(Vrms) |
1000 |
range of working temperature(℃) |
-55~+200 |
Minimum bending radius(mm) |
4 |
ROHS environmental |
meets |
frequency(GHz) |
attenuation(dB/m) |
1.0 |
2.3 |
2.0 |
3.1 |
3.0 |
3.9 |
4.0 |
4.6 |
5.0 |
5.1 |
6.0 |
5.8 |
project |
material |
diameter(mm) |
1.inner conductor |
silver plated copper wire |
7X0.08 |
2.insulator |
Polyperfluoroethylene propylene(FEP) |
0.68 |
3.outer conductor |
Silver plated copper wire braid |
Nom.0.88 |
4.jacket |
Polyperfluoroethylene propylene(FEP) |
1.13 |
capacitance(pF/m) |
95.6 |
impedance(ohm) |
50 |
Transmission rate(%) |
70 |
working frequency(GHz) |
6.0 |
Maximum working voltage(Vrms) |
1000 |
range of working temperature(℃) |
-55~+200 |
Minimum bending radius(mm) |
4 |
ROHS environmental |
meets |
frequency(GHz) |
attenuation(dB/m) |
1.0 |
2.3 |
2.0 |
3.1 |
3.0 |
3.9 |
4.0 |
4.6 |
5.0 |
5.1 |
6.0 |
5.8 |
project |
material |
diameter(mm) |
1.inner conductor |
silver plated copper wire |
7X0.064 |
2.insulator |
Polyperfluoroethylene propylene(FEP) |
0.53 |
3.outer conductor |
Silver plated copper wire braid |
Nom.0.75 |
4.jacket |
Polyperfluoroethylene propylene(FEP) |
0.98 |
capacitance(pF/m) |
100 |
impedance(ohm) |
50 |
Transmission rate(%) |
70 |
working frequency(GHz) |
6.0 |
Maximum working voltage(Vrms) |
1000 |
range of working temperature(℃) |
-55~+200 |
Minimum bending radius(mm) |
3 |
ROHS environmental |
meets |
frequency(GHz) |
attenuation(dB/m) |
1.0 |
2.8 |
2.0 |
4.1 |
3.0 |
5.3 |
4.0 |
6.4 |
5.0 |
7.3 |
6.0 |
8.2 |
project |
material |
diameter(mm) |
1.inner conductor |
silver plated copper wire |
7X0.03 |
2.insulator |
PFA |
0.25 |
3.outer conductor |
Silver plated copper wire braid |
Nom.0.32 |
4.jacket |
PFA |
0.38 |
capacitance(pF/m) |
100 |
impedance(ohm) |
50 |
Transmission rate(%) |
70 |
working frequency(GHz) |
1.0 |
Maximum working voltage(Vrms) |
50 |
range of working temperature(℃) |
-55~+200 |
ROHS environmental |
meets |
frequency(MHz) |
attenuation(dB/m) |
10 |
0.6 |
1000 |
6.0 |